| CVE ID | Title | Vendor | Product | Severity | CVSS Score | Published At | AI Analysis |
|---|---|---|---|---|---|---|---|
| CVE-2022-25164 | Mitsubishi Electric GX Works3 安全漏洞 | Mitsubishi Electric Corporation | GX Works3 | High | 8.6 | 2022-11-24 23:21:26 | Deep Dive |
| CVE-2022-1748 | Softing Secure Integration Server NULL Pointer Dereference | Softing | Secure Integration Server | High | 7.5 | 2022-08-17 20:08:38 | Deep Dive |
| CVE-2022-34765 | 多款Schneider Electric产品安全漏洞 | Schneider Electric | OPC UA Modicon Communication Module | Medium | 5.5 | 2022-07-13 21:11:13 | Deep Dive |
| CVE-2022-34764 | 多款Schneider Electric产品缓冲区错误漏洞 | Schneider Electric | OPC UA Modicon Communication Module | Medium | 5.9 | 2022-07-13 21:11:06 | Deep Dive |
| CVE-2022-34763 | 多款Schneider Electric产品数据伪造问题漏洞 | Schneider Electric | OPC UA Modicon Communication Module | Medium | 5.9 | 2022-07-13 21:11:02 | Deep Dive |
| CVE-2022-34762 | 多款Schneider Electric产品路径遍历漏洞 | Schneider Electric | OPC UA Modicon Communication Module | Medium | 5.9 | 2022-07-13 21:10:57 | Deep Dive |
| CVE-2022-34761 | 多款Schneider Electric产品代码问题漏洞 | Schneider Electric | OPC UA Modicon Communication Module | High | 7.5 | 2022-07-13 21:10:53 | Deep Dive |
| CVE-2022-34760 | 多款Schneider Electric产品安全漏洞 | Schneider Electric | OPC UA Modicon Communication Module | High | 7.5 | 2022-07-13 21:10:50 | Deep Dive |
| CVE-2022-34759 | 多款Schneider Electric产品缓冲区错误漏洞 | Schneider Electric | OPC UA Modicon Communication Module | High | 7.5 | 2022-07-13 21:10:47 | Deep Dive |
| CVE-2022-1794 | Plaintext Storage of a password in CODESYS V3 OPC DA Server | CODESYS | CODESYS OPC DA Server | Medium | 5.5 | 2022-07-11 10:40:28 | Deep Dive |
| CVE-2022-31805 | Insecure transmission of credentials | CODESYS | CODESYS Development System | High | 7.5 | 2022-06-24 07:46:15 | Deep Dive |
| CVE-2022-1261 | Matrikon OPC Server Improper Access Control | Matrikon, a subsidiary of Honeywell | Matrikon OPC Server | Medium | 5.8 | 2022-05-26 16:35:56 | Deep Dive |
| CVE-2021-32935 | Cognex In-Sight OPC Server - Deserialization of Untrusted Data | Cognex | In-Sight OPC Server | High | 8.8 | 2022-05-23 18:42:20 | Deep Dive |
| CVE-2022-22517 | Communication Components in multiple CODESYS products vulnerable to communication channel disruption | CODESYS | CODESYS Control RTE (SL) | High | 7.5 | 2022-04-07 18:21:20 | Deep Dive |
| CVE-2021-32994 | Softing OPC-UA C++ SDK Improper Restriction of Operations within the Bounds of a Memory Buffer | Softing | OPC UA C++ SDK (Software Development Kit) | High | 7.5 | 2022-04-04 19:45:58 | Deep Dive |
| CVE-2021-22284 | SECURITY - OPC Server for AC 800M - Remote Code Execution Vulnerability | ABB | 800xA, Control Software for AC 800M OPC Server for AC 800M | High | 8.4 | 2022-02-04 22:29:21 | Deep Dive |
| CVE-2021-34594 | Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server | Beckhoff Automation | TwinCAT OPC UA Server | Medium | 6.5 | 2021-11-04 09:50:09 | Deep Dive |
| CVE-2021-27432 | Siemens SIMATIC OPC UA 安全漏洞 | - | OPC Foundation OPC UA .NET Standard and OPC UA .NET Legacy | 高危 | - | 2021-05-20 15:20:01 | Deep Dive |
| CVE-2021-27434 | Siemens SIMATIC OPC UA 信息泄露漏洞 | - | OPC UA Products Built with the .NET Framework 4.5, 4.0, and 3.5 | 高危 | - | 2021-05-20 13:42:54 | Deep Dive |
| CVE-2020-12526 | BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server | Beckhoff | TwinCAT OPC UA Server | Medium | 5.3 | 2021-05-13 13:45:24 | Deep Dive |