| CVE-2022-0369 | Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability | Triangle MicroWorks | SCADA Data Gateway | - | - | 2024-05-07 22:54:55 | Deep Dive |
| CVE-2023-39468 | Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:30 | Deep Dive |
| CVE-2023-39467 | Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 中危 | - | 2024-05-03 01:59:30 | Deep Dive |
| CVE-2023-39466 | Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 中危 | - | 2024-05-03 01:59:29 | Deep Dive |
| CVE-2023-39465 | Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:28 | Deep Dive |
| CVE-2023-39464 | Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:27 | Deep Dive |
| CVE-2023-39463 | Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:27 | Deep Dive |
| CVE-2023-39462 | Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 中危 | - | 2024-05-03 01:59:26 | Deep Dive |
| CVE-2023-39461 | Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 中危 | - | 2024-05-03 01:59:25 | Deep Dive |
| CVE-2023-39460 | Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:24 | Deep Dive |
| CVE-2023-39459 | Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 高危 | - | 2024-05-03 01:59:24 | Deep Dive |
| CVE-2023-39458 | Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 中危 | - | 2024-05-03 01:59:23 | Deep Dive |
| CVE-2023-39457 | Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability | Triangle MicroWorks | SCADA Data Gateway | 超危 | - | 2024-05-03 01:59:22 | Deep Dive |
| CVE-2023-2187 | Triangle MicroWorks SCADA Data Gateway 安全漏洞 | Triangle MicroWorks | SCADA Data Gateway | Medium | 5.3 | 2023-06-07 06:42:31 | Deep Dive |
| CVE-2023-2186 | Triangle MicroWorks SCADA Data Gateway 格式化字符串错误漏洞 | Triangle MicroWorks | SCADA Data Gateway | High | 8.2 | 2023-06-07 06:37:33 | Deep Dive |
| CVE-2022-38138 | 多款Triangle Microworks产品缓冲区错误漏洞 | Triangle Microworks | Library: IEC 61850 | High | 7.5 | 2022-10-11 00:00:00 | Deep Dive |
| CVE-2020-6996 | Triangle MicroWorks DNP3 Outstation Libraries 缓冲区错误漏洞 | - | Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01 | 超危 | - | 2020-04-15 18:46:30 | Deep Dive |
| CVE-2020-10611 | Triangle MicroWorks SCADA Data Gateway 安全漏洞 | - | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | 超危 | - | 2020-04-15 18:36:16 | Deep Dive |
| CVE-2020-10613 | Triangle MicroWorks SCADA Data Gateway 缓冲区错误漏洞 | - | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | 高危 | - | 2020-04-15 18:30:42 | Deep Dive |
| CVE-2020-10615 | Triangle MicroWorks SCADA Data Gateway 缓冲区错误漏洞 | - | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | 高危 | - | 2020-04-15 18:28:01 | Deep Dive |