Vulnerability Description
An issue was discovered on KT MC01507L Z-Wave S0 devices. It occurs because HPKP is not implemented. The communication architecture is APP > Server > Controller (HUB) > Node (products which are controlled by HUB). The prerequisite is that the attacker is on the same network as the target HUB, and can use IP Changer to change destination IP addresses (of all packets whose destination IP address is Server) to a proxy-server IP address. This allows sniffing of cleartext between Server and Controller. The cleartext command data is transmitted to Controller using the proxy server's fake certificate, and it is able to control each Node of the HUB. Also, by operating HUB in Z-Wave Pairing Mode, it is possible to obtain the Z-Wave network key.
CVSS Information
N/A
Vulnerability Type
N/A
Vulnerability Title
KT MC01507L Z-Wave S0 安全漏洞
Vulnerability Description
KT MC01507L Z-Wave S0是韩国KT公司的一款电源管理设备。 KT MC01507L Z-Wave S0中存在安全漏洞,该漏洞源于程序没有启用HPKP机制。本地攻击者可利用该漏洞嗅探服务器和控制器之间的明文内容以及获取Z-Wave网络密钥。