Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%
Get alerts for future matching vulnerabilitiesLog in to subscribe
I. Basic Information for CVE-2020-27736
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
不恰当的空终结符
Source: NVD (National Vulnerability Database)
Vulnerability Title
多款siemens产品 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens TALON Series是德国西门子(Siemens)公司的一个开放系统。使控制器和应用程序在单个平台上运行,同时彼此互操作。 多款siemens产品存在缓冲区错误漏洞,攻击者可利用该漏洞导致拒绝服务或内存泄漏。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
SiemensAPOGEE PXC Compact (BACnet) All versions < V3.5.5 -
SiemensAPOGEE PXC Compact (P2 Ethernet) All versions < V2.8.20 -
SiemensAPOGEE PXC Modular (BACnet) All versions < V3.5.5 -
SiemensAPOGEE PXC Modular (P2 Ethernet) All versions < V2.8.20 -
SiemensNucleus NET All versions -
SiemensNucleus ReadyStart V3 All versions < V2017.02.3 -
SiemensNucleus ReadyStart V4 All versions < V4.1.0 -
SiemensNucleus Source Code Versions including affected DNS modules -
SiemensSIMOTICS CONNECT 400 All versions < V0.5.0.0 -
SiemensTALON TC Compact (BACnet) All versions < V3.5.5 -
SiemensTALON TC Modular (BACnet) All versions < V3.5.5 -
II. Public POCs for CVE-2020-27736
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2020-27736
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2020-27736

No comments yet


Leave a comment