Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2009-2685

Quick assessment

Affected
n/a n/a
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

HP Power Manager的管理web服务器中的登录格式中的栈缓冲区溢出允许远程攻击者借助登录变量,执行任意代码。

AI Predicted 9.8 Difficulty: Easy EPSS 76.71% · P100
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2009-2685

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Stack-based buffer overflow in the login form in the management web server in HP Power Manager allows remote attackers to execute arbitrary code via the Login variable.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
N/A
Source: CVE Program / CVE List V5
Vulnerability Title
HP Power Manager Web管理服务Login表格远程代码执行漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
HP Power Manager的管理web服务器中的登录格式中的栈缓冲区溢出允许远程攻击者借助登录变量,执行任意代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
- n/a n/a -

II. Public POCs for CVE-2009-2685

# POC Description Source Link Shenlong Link
1 Exploit for HP PowerManager - CVE 2009-2685 https://github.com/rflemen/CVE-2009-2685 POC Details
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2009-2685

请登录查看更多情报信息。

Vendor Advisories for CVE-2009-2685 (7)

Mailing List Discussions for CVE-2009-2685 (1)

Same Patch Batch · n/a · 2009-11-06 · 11 CVEs total

CVE-2009-3300 Internet2 Identity Provider多个跨站脚本漏洞
CVE-2009-3725 Linux Kernel连接器安全绕过漏洞
CVE-2009-3850 Blender '.blend' 文件 远程指令执行漏洞
CVE-2009-3899 Sun Solaris Sockets Direct Protocol (SDP) Driver 'sdp(7D)' 远程拒绝服务漏洞
CVE-2009-3900 IBM PowerHA 组件"Cluster Management" 未授权访问漏洞
CVE-2009-3901 e-Courier CMS多个跨站脚本攻击漏洞
CVE-2009-3902 Cherokee Web Server URL目录遍历漏洞
CVE-2009-3903 ManageEngine NetFlow Analyzer 'jspui/index.jsp' 跨站脚本攻击漏洞
CVE-2009-3904 CubeCart 'admin.php' 权限绕过漏洞
CVE-2009-3905 e-Courier CMS 'UserGUID'跨站脚本攻击漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2009-2685

No comments yet


Leave a comment