Affected
Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Abbott Accent等都是美国雅培(Abbott)公司的心脏起搏器设备。 多款Abbott产品中存在安全漏洞,该漏洞源于程序没有限制被正确格式化的‘RF wake-up’命令的数量。攻击者可通过重复的发送命令利用该漏洞缩短电池的寿命。以下产品和版本受到影响:Abbott Accent F0B.0E.7E之前的版本;Accent MRI F10.08.6C之前的版本;Accent ST F10.08.6C之前的版本;Allure F14.07.80之前的版本;Anthem F0B.0E.7E之前的版本

AI Predicted 5.3 Difficulty: Moderate EPSS 0.63% · P50
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2017-12714

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
CWE-920
Source: CVE Program / CVE List V5
Vulnerability Title
多款Abbott产品安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Abbott Accent等都是美国雅培(Abbott)公司的心脏起搏器设备。 多款Abbott产品中存在安全漏洞,该漏洞源于程序没有限制被正确格式化的‘RF wake-up’命令的数量。攻击者可通过重复的发送命令利用该漏洞缩短电池的寿命。以下产品和版本受到影响:Abbott Accent F0B.0E.7E之前的版本;Accent MRI F10.08.6C之前的版本;Accent ST F10.08.6C之前的版本;Allure F14.07.80之前的版本;Anthem F0B.0E.7E之前的版本
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. All versions of pacemakers manufactured prior to August 28, 2017 -

II. Public POCs for CVE-2017-12714

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2017-12714

请登录查看更多情报信息。

Vendor Advisories for CVE-2017-12714 (1)

Other References for CVE-2017-12714 (1)

Same Patch Batch · Abbott Laboratories · 2018-04-25 · 3 CVEs total

CVE-2017-12712 多款Abbott产品安全漏洞
CVE-2017-12716 多款Abbott产品信息泄露漏洞

IV. Related Vulnerabilities