Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Title
Rockwell Automation Allen-Bradley PowerMonitor 1000 访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Rockwell Automation Allen-Bradley PowerMonitor 1000是美国罗克韦尔(Rockwell Automation)公司的一款电源监控设备。 Rockwell Automation Allen-Bradley PowerMonitor 1000 存在访问控制错误漏洞。远程攻击者可通过发送特制的数据包利用该漏洞执行写入和读取操作,进而泄露敏感信息,修改设置或梯形逻辑。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
TalosAllen Bradley Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15 -
II. Public POCs for CVE-2017-14470
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2017-14470
Please Login to view more intelligence information
New Vulnerabilities
V. Comments for CVE-2017-14470

No comments yet


Leave a comment