Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2017-7915

Quick assessment

Affected
n/a Moxa OnCell
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

摩莎OnCell G3110-HSPA等都是摩莎(Moxa)公司的产品,其中OnCell G3110-HSPA是一款工业级的IP网关,OnCell 5104-HSPA是一款工业级蜂窝路由器。 多款摩莎产品存在安全漏洞。攻击者可利用该漏洞实施暴力破解。以下产品和版本受到影响:摩莎OnCell G3110-HSPA 1.3 build 15082117及之前的版本;OnCell G3110-HSDPA 1.2 Build 09123015及之前的版本;OnCell G3150-HSDPA 1.4 Build

AI Predicted 5.3 Difficulty: Easy EPSS 1.53% · P74

Possible ATT&CK Techniques 1 AI

T1110 · Brute Force
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2017-7915

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
过多认证尝试的限制不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
多款摩莎产品安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
摩莎OnCell G3110-HSPA等都是摩莎(Moxa)公司的产品,其中OnCell G3110-HSPA是一款工业级的IP网关,OnCell 5104-HSPA是一款工业级蜂窝路由器。 多款摩莎产品存在安全漏洞。攻击者可利用该漏洞实施暴力破解。以下产品和版本受到影响:摩莎OnCell G3110-HSPA 1.3 build 15082117及之前的版本;OnCell G3110-HSDPA 1.2 Build 09123015及之前的版本;OnCell G3150-HSDPA 1.4 Build
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
- Moxa OnCell Moxa OnCell -

II. Public POCs for CVE-2017-7915

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2017-7915

请登录查看更多情报信息。

Other References for CVE-2017-7915 (1)

Same Patch Batch · n/a · 2017-05-29 · 26 CVEs total

CVE-2017-9148 FreeRADIUS 安全漏洞
CVE-2017-9265 Open vSwitch 安全漏洞
CVE-2017-9264 Open vSwitch 安全漏洞
CVE-2017-9263 Open vSwitch 安全漏洞
CVE-2017-9262 ImageMagick 安全漏洞
CVE-2017-9261 ImageMagick 安全漏洞
CVE-2016-10377 Open vSwitch 安全漏洞
CVE-2017-9288 WordPress Raygun4WP插件跨站脚本漏洞
CVE-2017-9287 OpenLDAP 安全漏洞
CVE-2017-7917 多款摩莎产品跨站请求伪造漏洞
CVE-2017-7913 多款摩莎产品安全漏洞
CVE-2017-9292 Lansweeper 跨站脚本漏洞
CVE-2017-9289 Bram Korsten Note 跨站脚本漏洞
CVE-2017-9303 Laravel 安全漏洞
CVE-2017-9298 Hitachi Device Manager和Replication Manager 跨站脚本漏洞
CVE-2017-9297 Hitachi Device Manager 安全漏洞
CVE-2017-9296 Hitachi Device Manager和Replication Manager 安全漏洞
CVE-2017-9295 Hitachi Device Manager和Replication Manager 安全漏洞
CVE-2017-9294 Hitachi Device Manager 安全漏洞
CVE-2017-9302 RealNetworks RealPlayer 安全漏洞

Showing top 20 of 26 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2017-7915

No comments yet


Leave a comment