CVE-2018-16563— Siemens EN100 Ethernet Communication module和SIPROTEC 5 Relays 安全漏洞

一分钟漏洞结论

影响对象
Siemens Firmware variant IEC 61850 for EN100 Ethernet module
利用判断
尚无明确在野利用证据,仍需结合暴露面评估
建议动作
优先检查厂商安全公告和参考链接中的修复版本;无法立即升级时,限制受影响服务暴露并加强监测。

Siemens EN100 Ethernet Communication module和SIPROTEC 5 Relays中存在安全漏洞。攻击者可通过向受影响设备或模块发送多个数据包利用该漏洞造成拒绝服务。以下产品和版本受到影响:Siemens IEC 61850 for EN100 Ethernet module 4.35之前版本;MODBUS TCP for EN100 Ethernet module(所有版本);DNP3 TCP for EN100 Ethernet module(所有版本);IEC

AI 预测 7.5 利用难度: 中等 EPSS 1.16% · P66

可能的 ATT&CK 技术 1 AI

T1499 · Endpoint Denial of Service
获取后续新漏洞提醒 登录后订阅

一、 漏洞 CVE-2018-16563 基础信息

漏洞信息

对漏洞内容有疑问?看看神龙的深度分析是否有帮助!
查看神龙十问 ↗

尽管我们使用了先进的大模型技术,但其输出仍可能包含不准确或过时的信息。神龙努力确保数据的准确性,但请您根据实际情况进行核实和判断。

Vulnerability Title
N/A
来源: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
来源: CVE Program / CVE List V5
CVSS Information
N/A
来源: CVE Program / CVE List V5
Vulnerability Type
N/A
来源: CVE Program / CVE List V5
Vulnerability Title
Siemens EN100 Ethernet Communication module和SIPROTEC 5 Relays 安全漏洞
来源: 中国国家信息安全漏洞库 CNNVD
Vulnerability Description
Siemens EN100 Ethernet Communication module和SIPROTEC 5 Relays中存在安全漏洞。攻击者可通过向受影响设备或模块发送多个数据包利用该漏洞造成拒绝服务。以下产品和版本受到影响:Siemens IEC 61850 for EN100 Ethernet module 4.35之前版本;MODBUS TCP for EN100 Ethernet module(所有版本);DNP3 TCP for EN100 Ethernet module(所有版本);IEC
来源: 中国国家信息安全漏洞库 CNNVD
CVSS Information
N/A
来源: 中国国家信息安全漏洞库 CNNVD
Vulnerability Type
N/A
来源: 中国国家信息安全漏洞库 CNNVD

受影响产品

二、漏洞 CVE-2018-16563 的公开POC

# POC 描述 源链接 神龙链接
AI 生成 POC 高级

未找到公开 POC。

登录以生成 AI POC

三、漏洞 CVE-2018-16563 的情报信息

请登录查看更多情报信息。

CVE-2018-16563 厂商安全公告 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2018-16563

暂无评论


发表评论