Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2018-19001

Quick assessment

Affected
n/a Philips HealthSuite Health Android App
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Philips HealthSuite Health Android App是荷兰飞利浦(Philips)公司的一款基于Android平台的用于控制管理Philips可穿戴健康设备的应用程序。 Philips HealthSuite Health Android App(全部版本)中存在安全漏洞,该漏洞源于应用程序使用了较简单的加密。攻击者可利用该漏洞影响设备的完整性和保密性。

AI Predicted 5.9 Difficulty: Moderate EPSS 0.16% · P5

Possible ATT&CK Techniques 1 AI

T1557 · Adversary-in-the-Middle
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2018-19001

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
不充分的加密强度
Source: CVE Program / CVE List V5
Vulnerability Title
Philips HealthSuite Health Android App 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips HealthSuite Health Android App是荷兰飞利浦(Philips)公司的一款基于Android平台的用于控制管理Philips可穿戴健康设备的应用程序。 Philips HealthSuite Health Android App(全部版本)中存在安全漏洞,该漏洞源于应用程序使用了较简单的加密。攻击者可利用该漏洞影响设备的完整性和保密性。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
- Philips HealthSuite Health Android App All versions -

II. Public POCs for CVE-2018-19001

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2018-19001

请登录查看更多情报信息。

Vendor Advisories for CVE-2018-19001 (1)

Other References for CVE-2018-19001 (1)

Same Patch Batch · n/a · 2018-12-07 · 29 CVEs total

CVE-2018-5812 LibRaw 安全漏洞
CVE-2018-19932 GNU Binutils 输入验证错误漏洞
CVE-2018-19931 GNU Binutils 缓冲区错误漏洞
CVE-2018-19939 Xiaomi Mi A2 Lite和RedMi6 pro Goodix GT9xx触屏驱动程序代码问题漏洞
CVE-2018-19935 PHP 安全漏洞
CVE-2018-17924 多款Rockwell Automation产品安全漏洞
CVE-2018-19960 OnionShare 安全漏洞
CVE-2018-15362 GE Proficy CIMPLICITY 安全漏洞
CVE-2018-18314 Perl 缓冲区错误漏洞
CVE-2018-18313 Perl 缓冲区错误漏洞
CVE-2018-18311 Perl 输入验证错误漏洞
CVE-2018-5816 LibRaw 数字错误漏洞
CVE-2018-5815 LibRaw 数字错误漏洞
CVE-2018-5813 SUSE LibRaw 安全漏洞
CVE-2018-9572 Android 缓冲区错误漏洞
CVE-2018-5811 LibRaw 安全漏洞
CVE-2018-5810 SUSE LibRaw 缓冲区错误漏洞
CVE-2018-5809 LibRaw 缓冲区错误漏洞
CVE-2018-5808 LibRaw 缓冲区错误漏洞
CVE-2018-5807 LibRaw 安全漏洞

Showing top 20 of 29 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2018-19001

No comments yet


Leave a comment