Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2018-4843

Quick assessment

Affected
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens SIMATIC CP 343-1 Advanced是德国西门子(Siemens)公司的一款用于支持PROFINET(新一代基于工业以太网技术的自动化总线标准)的以太网通讯模块。 多款Siemens产品中存在输入验证错误漏洞。该漏洞源于网络系统或产品未对输入的数据进行正确的验证。以下产品及版本受到影响:Siemens SIMATIC CP 343-1 Advanced,SIMATIC CP 343-1 Standard,SIMATIC CP 443-1 Advanced,SIMATIC CP

CVSS 6.5 · Medium EPSS 0.54% · P44
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2018-4843

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.1), SIMATIC WinAC RTX 2010 (All versions < V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions < V2010 SP3), SINUMERIK 828D (All versions < V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system. The security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
输入验证不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens SIMATIC CP 343-1 Advanced 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens SIMATIC CP 343-1 Advanced是德国西门子(Siemens)公司的一款用于支持PROFINET(新一代基于工业以太网技术的自动化总线标准)的以太网通讯模块。 多款Siemens产品中存在输入验证错误漏洞。该漏洞源于网络系统或产品未对输入的数据进行正确的验证。以下产品及版本受到影响:Siemens SIMATIC CP 343-1 Advanced,SIMATIC CP 343-1 Standard,SIMATIC CP 443-1 Advanced,SIMATIC CP
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3 -
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions < V7.0.3 -
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions < V7.0.3 -
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 All versions < V7.0.3 -
Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) All versions -
Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) All versions -
Siemens SIMATIC CP 443-1 All versions < V3.3 -
Siemens SIMATIC CP 443-1 All versions < V3.3 -
Siemens SIMATIC CP 443-1 Advanced All versions < V3.3 -
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU All versions < V3.2.16 -
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU All versions < V3.2.16 -
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions < V3.2.16 -
Siemens SIMATIC ET 200S IM151-8 PN/DP CPU All versions < V3.2.16 -
Siemens SIMATIC ET 200S IM151-8F PN/DP CPU All versions < V3.2.16 -
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V1.7.0 -
Siemens SIMATIC S7-1500 Software Controller All versions < V1.7.0 -
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP All versions < V3.3.16 -
Siemens SIMATIC S7-300 CPU 315-2 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 317-2 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 319-3 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP All versions < V3.2.16 -
Siemens SIMATIC S7-400 CPU 412-2 PN V7 All versions < V7.0.3 -
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) All versions < V6.0.9 -
Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) All versions < V6.0.7 -
Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) All versions < V8.1 -

II. Public POCs for CVE-2018-4843

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2018-4843

请登录查看更多情报信息。

Vendor Advisories for CVE-2018-4843 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2018-4843

No comments yet


Leave a comment