Vulnerability Description
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
带着不必要的权限执行
Source: NVD (National Vulnerability Database)
Vulnerability Title
多款Philips Brilliance CT设备安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips Brilliance 64等都是荷兰飞利浦(Philips)公司的CT扫描仪设备。 多款Philips Brilliance CT设备中存在安全漏洞。攻击者可利用该漏洞获取提升的权限,并且获取底层Windows操作系统未授权资源的访问权限。以下产品和版本受到影响:Philips Brilliance 64 2.6.2及之前版本;Brilliance iCT 4.1.6及之前版本;Brillance iCT SP 3.2.4及之前版本;Brilliance CT Big Bore 2.3.5
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
PhilipsBrilliance CT Scanners Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. -
II. Public POCs for CVE-2018-8853
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2018-8853
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2018-8853

No comments yet


Leave a comment