CVE-2019-10964— Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control

Quick assessment

Affected
Medtronic MiniMed 508 pump
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Medtronic MiniMed 508 pump等都是美国美敦力(Medtronic)公司的一款胰岛素泵。 多款Medtronic产品中存在访问控制错误漏洞。该漏洞源于网络系统或产品未正确限制来自未授权角色的资源访问。以下产品及版本受到影响:MiniMed 508 pump(全部版本);MiniMed Paradigm 511 pump(全部版本);MiniMed Paradigm 512/712 pumps(全部版本);MiniMed Paradigm 712E pump(全部版本);MiniMed

CVSS 7.1 · High EPSS 1.23% · P68
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2019-10964

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control
Source: CVE Program / CVE List V5
Vulnerability Description
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
访问控制不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
多款Medtronic产品访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Medtronic MiniMed 508 pump等都是美国美敦力(Medtronic)公司的一款胰岛素泵。 多款Medtronic产品中存在访问控制错误漏洞。该漏洞源于网络系统或产品未正确限制来自未授权角色的资源访问。以下产品及版本受到影响:MiniMed 508 pump(全部版本);MiniMed Paradigm 511 pump(全部版本);MiniMed Paradigm 512/712 pumps(全部版本);MiniMed Paradigm 712E pump(全部版本);MiniMed
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Medtronic MiniMed 508 pump All versions -
Medtronic MiniMed Paradigm 511 pump All versions -
Medtronic MiniMed Paradigm 512/712 pumps All versions -
Medtronic MiniMed Paradigm 712E pump All versions -
Medtronic MiniMed Paradigm 515/715 pumps All versions -
Medtronic MiniMed Paradigm 522/722 pumps All versions -
Medtronic MiniMed Paradigm 522K/722K pumps All versions -
Medtronic MiniMed Paradigm 523/723 pumps 0 ~ Software Versions 2.4A -
Medtronic MiniMed Paradigm 523K/723K pumps 0 ~ Software Versions 2.4A -
Medtronic MiniMed Paradigm Veo 554/754 pumps 0 ~ Software Versions 2.6A -
Medtronic MiniMed Paradigm Veo 554CM/754CM pumps 0 ~ Software Versions 2.7A -

II. Public POCs for CVE-2019-10964

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-10964

请登录查看更多情报信息。

Vendor Advisories for CVE-2019-10964 (4)

IV. Related Vulnerabilities

V. Comments for CVE-2019-10964

No comments yet


Leave a comment