CVE-2019-13918

Quick assessment

Affected
Siemens AG SINEMA Remote Connect Server
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens SINEMA Remote Connect Server是德国西门子(Siemens)公司的一套远程网络管理平台。该平台主要用于远程访问、维护、控制和诊断底层网络。 Siemens SINEMA Remote Connect Server 2.0 SP1之前版本中存在安全漏洞。攻击者可利用该漏洞暴力破解密码,获取Web界面的全部访问权限。

AI Predicted 9.8 Difficulty: Moderate EPSS 1.51% · P74

Possible ATT&CK Techniques 1 AI

T1110 · Brute Force
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2019-13918

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
过多认证尝试的限制不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens SINEMA Remote Connect Server 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens SINEMA Remote Connect Server是德国西门子(Siemens)公司的一套远程网络管理平台。该平台主要用于远程访问、维护、控制和诊断底层网络。 Siemens SINEMA Remote Connect Server 2.0 SP1之前版本中存在安全漏洞。攻击者可利用该漏洞暴力破解密码,获取Web界面的全部访问权限。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens AG SINEMA Remote Connect Server All versions < V2.0 SP1 -

II. Public POCs for CVE-2019-13918

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-13918

请登录查看更多情报信息。

Vendor Advisories for CVE-2019-13918 (1)

Same Patch Batch · Siemens AG · 2019-09-13 · 6 CVEs total

CVE-2019-10937 Siemens SIMATIC TDC CP51M1 输入验证错误漏洞
CVE-2019-13919 西门子 SINEMA Remote Connect Server 安全漏洞
CVE-2019-13920 Siemens SINEMA Remote Connect Server 跨站请求伪造漏洞
CVE-2019-13922 Siemens SINEMA Remote Connect Server 安全漏洞
CVE-2019-13923 Siemens IE-WSN-PA Link WirelessHART Gateway 跨站脚本漏洞

IV. Related Vulnerabilities