Support Us — Your donation helps us keep running

Goal: 1000 CNY,Raised: 1000 CNY

100.0%
Get alerts for future matching vulnerabilitiesLog in to subscribe
I. Basic Information for CVE-2019-13924
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
保护机制失效
Source: NVD (National Vulnerability Database)
Vulnerability Title
Siemens Scalance X-200 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Scalance X-200是德国西门子(Siemens)公司的一款工业级以太网交换机。 Siemens SCALANCE X-200 中存在输入验证错误漏洞,该漏洞源于设备在管理Web接口中所发送的响应头并不包含X-Frame-Option。攻击者可利用该漏洞劫持其他用户的点击操作。以下产品及版本受到影响:Siemens SCALANCE X-200 5.2.4之前版本、SCALANCE X-200IRT(全部版本)和SCALANCE X-300 4.1.3之前版本。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
SiemensSCALANCE S602 All versions < V4.1 -
SiemensSCALANCE S612 All versions < V4.1 -
SiemensSCALANCE S623 All versions < V4.1 -
SiemensSCALANCE S627-2M All versions < V4.1 -
SiemensSCALANCE X-200 switch family (incl. SIPLUS NET variants) All versions < 5.2.4 -
SiemensSCALANCE X-200IRT switch family (incl. SIPLUS NET variants) All versions < V5.5.0 -
SiemensSCALANCE X-200RNA switch family All versions < V3.2.7 -
SiemensSCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) All versions < 4.1.3 -
II. Public POCs for CVE-2019-13924
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2019-13924
Please Login to view more intelligence information
New Vulnerabilities
V. Comments for CVE-2019-13924

No comments yet


Leave a comment