Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2019-25716— Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Quick assessment

Affected
Dräger Infinity Delta
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Dräger Infinity Delta等都是德国Dräger公司的产品。Dräger Infinity Delta是一款多参数临床监护仪。Dräger Infinity Kappa是一款多参数患者监护仪。Dräger Infinity Delta XL是一款高性能多参数患者监护仪。 Dräger多款产品存在安全漏洞,该漏洞源于拒绝服务,可能导致远程攻击者通过发送畸形网络数据包导致监视器重启。以下产品受到影响:Dräger Infinity Delta、Dräger Infinity Delta XL和

CVSS 6.5 · Medium EPSS 0.41% · P34

Possible ATT&CK Techniques 1 AI

T1499 · Endpoint Denial of Service

Affected Version Matrix 3

VendorProduct Version RangeStatus
Dräger Infinity Delta Infinity Delta affected
Dräger Infinity Delta XL Infinity Delta XL affected
Dräger Infinity Kappa Infinity Kappa affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2019-25716

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
Source: CVE Program / CVE List V5
Vulnerability Description
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
系统设置或配置在外部可控制
Source: CVE Program / CVE List V5
Vulnerability Title
Dräger多款产品 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Dräger Infinity Delta等都是德国Dräger公司的产品。Dräger Infinity Delta是一款多参数临床监护仪。Dräger Infinity Kappa是一款多参数患者监护仪。Dräger Infinity Delta XL是一款高性能多参数患者监护仪。 Dräger多款产品存在安全漏洞,该漏洞源于拒绝服务,可能导致远程攻击者通过发送畸形网络数据包导致监视器重启。以下产品受到影响:Dräger Infinity Delta、Dräger Infinity Delta XL和
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Dräger Infinity Delta Infinity Delta -
Dräger Infinity Delta XL Infinity Delta XL -
Dräger Infinity Kappa Infinity Kappa -

II. Public POCs for CVE-2019-25716

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-25716

登录查看更多情报信息。

Vendor Advisories for CVE-2019-25716 (2)

IV. Related Vulnerabilities

V. Comments for CVE-2019-25716

No comments yet


Leave a comment