Vulnerability Description
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
在Web页面生成时对输入的转义处理不恰当(跨站脚本)
Source: NVD (National Vulnerability Database)
Vulnerability Title
多款路由器命令操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
多款路由器中存在命令操作系统命令注入漏洞。该漏洞源于外部输入数据构造可执行命令过程中,网络系统或产品未正确过滤其中的特殊元素。攻击者可利用该漏洞执行非法命令。以下产品及版本受到影响:使用1.6.0.2版本固件的Crestron AM-100;使用2.7.0.1版本固件的Crestron AM-101;使用2.3.0.10版本固件的Barco wePresent WiPG-1000P;使用2.4.1.19之前版本固件的Barco wePresent WiPG-1600W;使用2.0.3.4版本固件的Extr
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
II. Public POCs for CVE-2019-3929
#POC DescriptionSource LinkShenlong Link
1Crestron/Barco/Extron/InFocus/TeqAV Remote Command Injection (CVE-2019-3929) Metasploit Modulehttps://github.com/xfox64x/CVE-2019-3929POC Details
2The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2019/CVE-2019-3929.yamlPOC Details
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2019-3929
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2019-3929

No comments yet


Leave a comment