Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2019-3929

Quick assessment

Affected
Crestron Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.
Exploitation
Confirmed exploitation in the wild; remediate immediately
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

多款路由器中存在命令操作系统命令注入漏洞。该漏洞源于外部输入数据构造可执行命令过程中,网络系统或产品未正确过滤其中的特殊元素。攻击者可利用该漏洞执行非法命令。以下产品及版本受到影响:使用1.6.0.2版本固件的Crestron AM-100;使用2.7.0.1版本固件的Crestron AM-101;使用2.3.0.10版本固件的Barco wePresent WiPG-1000P;使用2.4.1.19之前版本固件的Barco wePresent WiPG-1600W;使用2.0.3.4版本固件的Extr

AI Predicted 9.8 Difficulty: Trivial KEV EPSS 98.95% · P100

Possible ATT&CK Techniques 1 AI

T1059 · Command and Scripting Interpreter
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2019-3929

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
在Web页面生成时对输入的转义处理不恰当(跨站脚本)
Source: CVE Program / CVE List V5
Vulnerability Title
多款路由器命令操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
多款路由器中存在命令操作系统命令注入漏洞。该漏洞源于外部输入数据构造可执行命令过程中,网络系统或产品未正确过滤其中的特殊元素。攻击者可利用该漏洞执行非法命令。以下产品及版本受到影响:使用1.6.0.2版本固件的Crestron AM-100;使用2.7.0.1版本固件的Crestron AM-101;使用2.3.0.10版本固件的Barco wePresent WiPG-1000P;使用2.4.1.19之前版本固件的Barco wePresent WiPG-1600W;使用2.0.3.4版本固件的Extr
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

II. Public POCs for CVE-2019-3929

# POC Description Source Link Shenlong Link
1 Crestron/Barco/Extron/InFocus/TeqAV Remote Command Injection (CVE-2019-3929) Metasploit Module https://github.com/xfox64x/CVE-2019-3929 POC Details
2 The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2019/CVE-2019-3929.yaml POC Details
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-3929

请登录查看更多情报信息。

Exploits & Public PoCs for CVE-2019-3929 (2)

Other References for CVE-2019-3929 (1)

Same Patch Batch · Crestron · 2019-04-30 · 15 CVEs total

CVE-2019-3925 Crestron Electronics AM-100和Crestron Electronics AM-101 命令操作系统命令注入漏洞
CVE-2019-3926 Crestron Electronics AM-100和Crestron Electronics AM-101 命令操作系统命令注入漏洞
CVE-2019-3927 Crestron Electronics AM-100和Crestron Electronics AM-101 授权问题漏洞
CVE-2019-3928 Crestron Electronics AM-101 安全漏洞
CVE-2019-3930 多款路由器缓冲区错误漏洞
CVE-2019-3931 Crestron Electronics AM-100和Crestron Electronics AM-101 参数注入漏洞
CVE-2019-3932 Crestron Electronics AM-100和Crestron Electronics AM-101 信任管理问题漏洞
CVE-2019-3933 Crestron Electronics AM-100和Crestron Electronics AM-101 访问控制错误漏洞
CVE-2019-3934 Crestron Electronics AM-100和Crestron Electronics AM-101 访问控制错误漏洞
CVE-2019-3935 Crestron AM-101 安全漏洞
CVE-2019-3936 Crestron Electronics AM-100和Crestron Electronics AM-101 输入验证错误漏洞
CVE-2019-3937 Crestron Electronics AM-100和Crestron Electronics AM-101 信任管理问题漏洞
CVE-2019-3938 Crestron Electronics AM-100和Crestron Electronics AM-101 信任管理问题漏洞
CVE-2019-3939 Crestron Electronics AM-100和Crestron Electronics AM-101 信任管理问题漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2019-3929

No comments yet


Leave a comment