Affected
ProClima ProClima all versions prior to version 8.0.0
Exploitation
High exploitation probability; assess promptly
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric ProClima是法国施耐德电气(Schneider Electric)公司的一套热量计算软件。该软件通过分析指定的热量数据,为控制面板内安装的环境和电气/电子设备提供热量管理功能。 Schneider Electric ProClima 8.0.0之前版本中存在代码注入漏洞。该漏洞源于外部输入数据构造代码段的过程中,网络系统或产品未正确过滤其中的特殊元素。攻击者可利用该漏洞生成非法的代码段,修改网络系统或组件的预期的执行控制流。

AI Predicted 10.0 Difficulty: Trivial EPSS 4.95% · P92
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2019-6823

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
对生成代码的控制不恰当(代码注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric ProClima 代码注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric ProClima是法国施耐德电气(Schneider Electric)公司的一套热量计算软件。该软件通过分析指定的热量数据,为控制面板内安装的环境和电气/电子设备提供热量管理功能。 Schneider Electric ProClima 8.0.0之前版本中存在代码注入漏洞。该漏洞源于外部输入数据构造代码段的过程中,网络系统或产品未正确过滤其中的特殊元素。攻击者可利用该漏洞生成非法的代码段,修改网络系统或组件的预期的执行控制流。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
ProClima ProClima all versions prior to version 8.0.0 ProClima all versions prior to version 8.0.0 -

II. Public POCs for CVE-2019-6823

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-6823

请登录查看更多情报信息。

Other References for CVE-2019-6823 (1)

Same Patch Batch · ProClima · 2019-07-15 · 3 CVEs total

CVE-2019-6824 Schneider Electric ProClima 缓冲区错误漏洞
CVE-2019-6825 Schneider Electric ProClima 代码问题漏洞