Support Us — Your donation helps us keep running

Goal: 1000 CNY,Raised: 1000 CNY

100.0%
Get alerts for future matching vulnerabilitiesLog in to subscribe
I. Basic Information for CVE-2020-14477
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Philips Ultrasound Systems Authentication Bypass Using an Alternate Path or Channel
Source: NVD (National Vulnerability Database)
Vulnerability Description
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N
Source: NVD (National Vulnerability Database)
Vulnerability Type
使用候选路径或通道进行的认证绕过
Source: NVD (National Vulnerability Database)
Vulnerability Title
多款Philips产品授权问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips Ultrasound ClearVue等都是欧洲飞利浦(Philips)公司的一款用于医疗行业的超声波检查器。 多款Philips产品中存在安全漏洞。攻击者可利用该漏洞查看或修改信息。以下产品及版本受到影响:Ultrasound ClearVue Versions 3.2及之前版本;Ultrasound CX Versions 5.0.2及之前版本;Ultrasound EPIQ/Affiniti Versions VM5.0及之前版本;Ultrasound Sparq Version 3
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
PhilipsUltrasound ClearVue 0 ~ versions 3.2 -
PhilipsUltrasound CX 0 ~ versions 5.0.2 -
PhilipsUltrasound EPIQ/Affiniti 0 ~ versions VM5.0 -
PhilipsUltrasound Sparq 0 ~ version 3.0.2 -
PhilipsUltrasound Xperius all versions -
II. Public POCs for CVE-2020-14477
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2020-14477
Please Login to view more intelligence information
New Vulnerabilities
V. Comments for CVE-2020-14477

No comments yet


Leave a comment