Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2020-5344

Quick assessment

Affected
Dell Integrated Dell Remote Access Controller (iDRAC)
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Dell EMC iDRAC9等都是美国戴尔(Dell)公司的产品。Dell EMC iDRAC9是一套包含硬件和软件的系统管理解决方案。Dell EMC iDRAC7是一套包含硬件和软件的系统管理解决方案。Dell EMC iDRAC8是一套包含硬件和软件的系统管理解决方案。 Dell EMC iDRAC7 2.65.65.65之前版本、iDRAC8 2.70.70.70之前版本和iDRAC9 4.00.00.00之前版本中存在缓冲区错误漏洞。远程攻击者可借助特制的输入数据利用该漏洞在系统上执行代码。

CVSS 7.0 · High EPSS 3.84% · P89
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2020-5344

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Dell EMC iDRAC7、iDRAC8和iDRAC9 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Dell EMC iDRAC9等都是美国戴尔(Dell)公司的产品。Dell EMC iDRAC9是一套包含硬件和软件的系统管理解决方案。Dell EMC iDRAC7是一套包含硬件和软件的系统管理解决方案。Dell EMC iDRAC8是一套包含硬件和软件的系统管理解决方案。 Dell EMC iDRAC7 2.65.65.65之前版本、iDRAC8 2.70.70.70之前版本和iDRAC9 4.00.00.00之前版本中存在缓冲区错误漏洞。远程攻击者可借助特制的输入数据利用该漏洞在系统上执行代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Dell Integrated Dell Remote Access Controller (iDRAC) unspecified ~ 2.65.65.65 -

II. Public POCs for CVE-2020-5344

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2020-5344

登录查看更多情报信息。

Other References for CVE-2020-5344 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2020-5344

No comments yet


Leave a comment