Support Us — Your donation helps us keep running

Goal: 1000 CNY,Raised: 1000 CNY

100.0%
Get alerts for future matching vulnerabilitiesLog in to subscribe
I. Basic Information for CVE-2020-6966
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
不充分的加密强度
Source: NVD (National Vulnerability Database)
Vulnerability Title
多款GE产品加密问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
多款GE产品中存在加密问题漏洞,该漏洞源于远程桌面控制使用了弱加密方式。远程攻击者可利用该漏洞执行任意代码。以下产品及版本受到影响:ApexPro Telemetry Server 4.2及之前版本;CARESCAPE Telemetry Server v4.2及之前版本;Clinical Information Center (CIC) 4.X版本,5.X版本; CARESCAPE Telemetry Server 4.3版本;CARESCAPE Central Station (CSCS) 1.X版本
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
-GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server, v4.2 & prior,Clinical Information Center,v4.X& 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850 -
II. Public POCs for CVE-2020-6966
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2020-6966
Please Login to view more intelligence information
New Vulnerabilities
V. Comments for CVE-2020-6966

No comments yet


Leave a comment