Siemens SIMATIC WinCC是德国西门子(Siemens)公司的一套自动化的数据采集与监控(SCADA)系统。 SIMATIC WinCC存在安全漏洞。该漏洞源于程序存在一个超出范围的内存访问漏洞,这可能导致代码执行。
| 厂商 | 产品 | 版本范围 | 状态 |
|---|---|---|---|
| Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) | All versions < V15.1 Update 6 |
affected |
| Siemens | SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) | All versions < V16 Update 4 |
affected |
| Siemens | SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) | All versions < V15.1 Update 6 |
affected |
| Siemens | SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) | All versions < V16 Update 4 |
affected |
| Siemens | SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F | All versions < V15.1 Update 6 |
affected |
| Siemens | SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F | All versions < V16 Update 4 |
affected |
| Siemens | SIMATIC WinCC Runtime Advanced V15 | All versions < V15.1 Update 6 |
affected |
| Siemens | SIMATIC WinCC Runtime Advanced V16 | All versions < V16 Update 4 |
affected |
尽管我们使用了先进的大模型技术,但其输出仍可能包含不准确或过时的信息。神龙努力确保数据的准确性,但请您根据实际情况进行核实和判断。
| 厂商 | 产品 | 影响版本 | CPE | 订阅 |
|---|---|---|---|---|
| Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) | All versions < V15.1 Update 6 | - |
|
| Siemens | SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) | All versions < V16 Update 4 | - |
|
| Siemens | SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) | All versions < V15.1 Update 6 | - |
|
| Siemens | SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) | All versions < V16 Update 4 | - |
|
| Siemens | SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F | All versions < V15.1 Update 6 | - |
|
| Siemens | SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F | All versions < V16 Update 4 | - |
|
| Siemens | SIMATIC WinCC Runtime Advanced V15 | All versions < V15.1 Update 6 | - |
|
| Siemens | SIMATIC WinCC Runtime Advanced V16 | All versions < V16 Update 4 | - |
|
| # | POC 描述 | 源链接 | 神龙链接 |
|---|
未找到公开 POC。
登录以生成 AI POC| CVE-2021-27385 | Siemens SmartVNC 资源管理错误漏洞 | |
| CVE-2021-27386 | Siemens SIMATIC WinCC 缓冲区错误漏洞 | |
| CVE-2021-27396 | Siemens Tecnomatix Plant Simulation 安全漏洞 | |
| CVE-2021-27397 | Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞 | |
| CVE-2021-27398 | siemens Tecnomatix RobotExpert 安全漏洞 | |
| CVE-2021-31339 | Siemens Mendix 安全漏洞 | |
| CVE-2020-25242 | 多款 Siemens 设备资源管理错误漏洞 | |
| CVE-2021-25660 | Siemens SIMATIC WinCC 缓冲区错误漏洞 | |
| CVE-2021-25662 | Siemens SIMATIC WinCC 安全漏洞 | |
| CVE-2021-27383 | Siemens SmartVNC 缓冲区错误漏洞 | |
| CVE-2021-27384 | Siemens SIMATIC WinCC 安全漏洞 | |
| CVE-2019-19276 | 多款 Siemens 设备缓冲区错误漏洞 |