Vulnerability Information
Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.
Vulnerability Title
N/A
Vulnerability Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vulnerability Type
CWE-1284
Vulnerability Title
Siemens Nucleus 安全漏洞
Vulnerability Description
Siemens Nucleus是德国西门子(Siemens)公司的一个工控设备。提供一个工控设备。 Siemens Nucleus 存在安全漏洞,该漏洞源于 UDP 有效负载的总长度(在 IP 标头中设置)未选中。这可能会导致各种副作用,包括信息泄漏和拒绝服务条件,具体取决于运行在 UDP 协议之上的用户定义的应用程序。
CVSS Information
N/A
Vulnerability Type
N/A