Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2022-22170— Junos OS: Specific packets over VXLAN cause FPC memory leak and ultimately reset

Quick assessment

Affected
Juniper Networks Junos OS
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Juniper Networks Junos OS是美国瞻博网络(Juniper Networks)公司的一套专用于该公司的硬件设备的网络操作系统。该操作系统提供了安全编程接口和Junos SDK。 Juniper Networks Junos OS 存在代码问题漏洞,该漏洞源于数据包转发引擎(PFE)内存泄漏。攻击者可利用该漏洞通过VXLAN发送特定数据包,重置FPC执行拒绝服务攻击。

CVSS 7.5 · High EPSS 0.93% · P59
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2022-22170

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Junos OS: Specific packets over VXLAN cause FPC memory leak and ultimately reset
Source: CVE Program / CVE List V5
Vulnerability Description
A Missing Release of Resource after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a Denial of Service (DoS) by sending specific packets over VXLAN which cause heap memory to leak and on exhaustion the PFE to reset. The heap memory utilization can be monitored with the command: user@host> show chassis fpc This issue affects: Juniper Networks Junos OS 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect versions of Junos OS prior to 19.4R1.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
N/A
Source: CVE Program / CVE List V5
Vulnerability Title
Juniper Networks Junos OS 代码问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Juniper Networks Junos OS是美国瞻博网络(Juniper Networks)公司的一套专用于该公司的硬件设备的网络操作系统。该操作系统提供了安全编程接口和Junos SDK。 Juniper Networks Junos OS 存在代码问题漏洞,该漏洞源于数据包转发引擎(PFE)内存泄漏。攻击者可利用该漏洞通过VXLAN发送特定数据包,重置FPC执行拒绝服务攻击。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Juniper Networks Junos OS unspecified ~ 19.4R1 -

II. Public POCs for CVE-2022-22170

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-22170

请登录查看更多情报信息。

Vendor Advisories for CVE-2022-22170 (1)

Same Patch Batch · Juniper Networks · 2022-01-19 · 27 CVEs total

CVE-2022-22152 7.7 HIGH Contrail Service Orchestration: Tenants able to see other tenants policies via REST API in
CVE-2022-22153 7.5 HIGH SRX Series and MX Series with SPC3: A high percentage of fragments might lead to high late
CVE-2022-22180 7.5 HIGH Junos OS: EX2300 Series, EX2300-MP Series, EX3400 Series: A slow memory leak due to proces
CVE-2022-22178 7.5 HIGH Junos OS: MX and SRX series: Flowd core observed if the SIP ALG is enabled and a specific
CVE-2022-22175 7.5 HIGH Junos OS: MX Series and SRX Series: The flowd daemon will crash if the SIP ALG is enabled
CVE-2022-22174 7.5 HIGH Junos OS: QFX5000 Series, EX4600: Device may run out of memory, causing traffic loss, upon
CVE-2022-22173 7.5 HIGH Junos OS: CRL failing to download causes a memory leak and ultimately a DoS
CVE-2022-22171 7.5 HIGH Junos OS: Specific packets over VXLAN cause FPC reset
CVE-2022-22161 7.5 HIGH Junos OS: MX104 might become unresponsive if the out-of-band management port receives a fl
CVE-2022-22159 7.5 HIGH Junos OS: An attacker sending crafted packets can cause a traffic and CPU Denial of Servic
CVE-2022-22163 7.4 HIGH Junos OS: jdhcpd crashes upon receipt of a specific DHCPv6 packet
CVE-2022-22176 7.4 HIGH Junos OS: In a scenario with dhcp-security and option-82 configured jdhcpd crashes upon re
CVE-2022-22162 7.3 HIGH Junos OS: A low privileged user can elevate their privileges to the ones of the highest pr
CVE-2022-22167 7.2 HIGH Junos OS: SRX Series: If no-syn-check is enabled, traffic classified as UNKNOWN gets permi
CVE-2022-22157 7.2 HIGH Junos OS: SRX Series: Traffic classification vulnerability when 'no-syn-check' is enabled
CVE-2022-22154 6.8 MEDIUM Junos Fusion: A Satellite Device can be controlled by rewiring it to a foreign AD causing
CVE-2022-22160 6.5 MEDIUM Junos OS: MX Series: The bbe-smgd process crashes if an unsupported configuration exists a
CVE-2022-22172 6.5 MEDIUM Junos OS and Junos OS Evolved: An l2cpd memory leak can occur when specific LLDP packets a
CVE-2022-22168 6.5 MEDIUM Junos OS: vMX and MX150: Specific packets might cause a memory leak and eventually an FPC
CVE-2022-22156 6.5 MEDIUM Junos OS: Certificate validation is skipped when fetching system scripts from a HTTPS URL

Showing top 20 of 27 CVEs. View all on vendor page → →