Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2022-29922— A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...

Quick assessment

Affected
Hitachi Energy MicroSCADA X SYS600
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Hitachi Energy MicroSCADA X SYS600是日本Hitachi公司的一款 SCADA 产品。通过不同设备和系统之间的无缝集成和连接,确保您的开关站的优化控制和可靠运行。 Hitachi Energy MicroSCADA X SYS600 10.3.1及之前版本和9.4 FP2 Hotfix 4 及之前版本存在安全漏洞,该漏洞源于在处理具有有效数据项但数据类型不正确的特制数据包时存在问题,该漏洞可能会导致服务器部分出现拒绝服务。

CVSS 7.5 · High EPSS 0.71% · P50

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2022-29922

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...
Source: CVE Program / CVE List V5
Vulnerability Description
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
输入验证不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Hitachi Energy MicroSCADA X SYS600 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Hitachi Energy MicroSCADA X SYS600是日本Hitachi公司的一款 SCADA 产品。通过不同设备和系统之间的无缝集成和连接,确保您的开关站的优化控制和可靠运行。 Hitachi Energy MicroSCADA X SYS600 10.3.1及之前版本和9.4 FP2 Hotfix 4 及之前版本存在安全漏洞,该漏洞源于在处理具有有效数据项但数据类型不正确的特制数据包时存在问题,该漏洞可能会导致服务器部分出现拒绝服务。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Hitachi Energy MicroSCADA X SYS600 10 -
Hitachi Energy MicroSCADA Pro SYS600 unspecified ~ 9.2 FP2 Hotfix 4 -

II. Public POCs for CVE-2022-29922

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-29922

登录查看更多情报信息。

Other References for CVE-2022-29922 (1)

Same Patch Batch · Hitachi Energy · 2022-09-14 · 4 CVEs total

CVE-2022-2277 7.5 HIGH A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation
CVE-2022-1778 7.5 HIGH A vulnerability exists during the start of the affected SYS600, where an input validation
CVE-2022-29492 5.3 MEDIUM A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a

IV. Related Vulnerabilities

V. Comments for CVE-2022-29922

No comments yet


Leave a comment