Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2022-39099

Quick assessment

Affected
Unisoc (Shanghai) Technologies Co., Ltd. SC9863A/SC9832E/SC7731E/T610/T310/T606/T760/T610/T618/T606/T612/T616/T760/T770/T820/S8000
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

UNISOC chipset是中国紫光展锐(UNISOC)公司的一个集成电路芯片组。 UNISOC chipset 存在安全漏洞,该漏洞源于在电源管理服务中,缺少权限检查,这可能导致设置电源管理服务而无需额外的执行权限。

AI Predicted 7.8 Difficulty: Easy EPSS 0.15% · P4

Possible ATT&CK Techniques 1 AI

T1098 · Account Manipulation
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2022-39099

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
授权机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
UNISOC chipset 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
UNISOC chipset是中国紫光展锐(UNISOC)公司的一个集成电路芯片组。 UNISOC chipset 存在安全漏洞,该漏洞源于在电源管理服务中,缺少权限检查,这可能导致设置电源管理服务而无需额外的执行权限。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Unisoc (Shanghai) Technologies Co., Ltd. SC9863A/SC9832E/SC7731E/T610/T310/T606/T760/T610/T618/T606/T612/T616/T760/T770/T820/S8000 Android10/Android11/Android12 -

II. Public POCs for CVE-2022-39099

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-39099

登录查看更多情报信息。

Other References for CVE-2022-39099 (1)

Same Patch Batch · Unisoc (Shanghai) Technologies Co., Ltd. · 2022-12-06 · 49 CVEs total

CVE-2022-42769 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42772 Google Pixel 缓冲区错误漏洞
CVE-2022-42774 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42778 UNISOC chipset 安全漏洞
CVE-2022-42779 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42780 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42781 UNISOC chipset缓冲区错误漏洞
CVE-2022-42782 UNISOC chipset 安全漏洞
CVE-2022-42777 UNISOC chipset 安全漏洞
CVE-2022-42770 Google Pixel 竞争条件问题漏洞
CVE-2022-42771 Google Pixel 竞争条件问题漏洞
CVE-2022-42768 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42767 UNISOC chipset 输入验证错误漏洞
CVE-2022-42766 UNISOC chipset 安全漏洞
CVE-2022-42765 UNISOC chipset 输入验证错误漏洞
CVE-2022-42764 UNISOC chipset 输入验证错误漏洞
CVE-2022-42763 UNISOC chipset 输入验证错误漏洞
CVE-2022-42762 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42761 UNISOC chipset 缓冲区错误漏洞
CVE-2022-42760 UNISOC chipset 安全漏洞

Showing top 20 of 49 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2022-39099

No comments yet


Leave a comment