Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2022-41671

Quick assessment

Affected
Schneider Electric EcoStruxure Operator Terminal Expert
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric EcoStruxure Operator Terminal Expert是法国施耐德电气(Schneider Electric)公司的一款触控屏配置软件。该软件支主要用于创建和编辑触控应用程序。 Schneider Electric EcoStruxure Operator Terminal Expert V3.3版本及之前版本、Pro face BLUE V3.3版本及之前版本存在SQL注入漏洞,该漏洞源于。

CVSS 7.0 · High EPSS 0.26% · P16

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2022-41671

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
SQL命令中使用的特殊元素转义处理不恰当(SQL注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric EcoStruxure Operator Terminal Expert SQL注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric EcoStruxure Operator Terminal Expert是法国施耐德电气(Schneider Electric)公司的一款触控屏配置软件。该软件支主要用于创建和编辑触控应用程序。 Schneider Electric EcoStruxure Operator Terminal Expert V3.3版本及之前版本、Pro face BLUE V3.3版本及之前版本存在SQL注入漏洞,该漏洞源于。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric EcoStruxure Operator Terminal Expert V3.3 ~ Hotfix 1 -
Schneider Electric Pro-face BLUE V3.3 ~ Hotfix 1 -

II. Public POCs for CVE-2022-41671

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-41671

请登录查看更多情报信息。

Other References for CVE-2022-41671 (1)

Same Patch Batch · Schneider Electric · 2022-11-04 · 6 CVEs total

CVE-2022-41666 7.0 HIGH Schneider Electric EcoStruxure Operator Terminal Expert 数据伪造问题漏洞
CVE-2022-41667 7.0 HIGH Schneider Electric EcoStruxure Operator Terminal Expert 路径遍历漏洞
CVE-2022-41668 7.0 HIGH Schneider Electric EcoStruxure Operator Terminal Expert 代码问题漏洞
CVE-2022-41669 7.0 HIGH Schneider Electric EcoStruxure Operator Terminal Expert 数据伪造问题漏洞
CVE-2022-41670 7.0 HIGH Schneider Electric EcoStruxure Operator Terminal Expert 路径遍历漏洞

IV. Related Vulnerabilities