Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2023-29122— Incorrect file ownership of privileged service's libraries in Enel X JuiceBox

Quick assessment

Affected
Enel X JuiceBox Pro 3.0 22kW Cellular
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Enel X Waybox是Enel X公司的一个家庭充电站。 Enel X Waybox 3.0版本存在安全漏洞,该漏洞源于特权服务库的文件所有权不正确,导致攻击者将能够以root用户的权限执行任意操作系统命令。

CVSS 6.7 · Medium EPSS 0.17% · P5
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2023-29122

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Incorrect file ownership of privileged service's libraries in Enel X JuiceBox
Source: CVE Program / CVE List V5
Vulnerability Description
Under certain conditions, access to service libraries is granted to account they should not have access to.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
不正确的属主授予
Source: CVE Program / CVE List V5
Vulnerability Title
Enel X Waybox 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Enel X Waybox是Enel X公司的一个家庭充电站。 Enel X Waybox 3.0版本存在安全漏洞,该漏洞源于特权服务库的文件所有权不正确,导致攻击者将能够以root用户的权限执行任意操作系统命令。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Enel X JuiceBox Pro 3.0 22kW Cellular 0 ~ 2.1.1.0_JB3VU096A -

II. Public POCs for CVE-2023-29122

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2023-29122

请登录查看更多情报信息。

Other References for CVE-2023-29122 (1)

Same Patch Batch · Enel X · 2024-11-05 · 11 CVEs total

CVE-2023-29120 9.6 CRITICAL Unauthorized Remote Command Execution in Enel X Juicebox
CVE-2023-29119 9.6 CRITICAL Unauthorized SQLite Injection
CVE-2023-29118 9.6 CRITICAL Unauthorized SQLite Injection in Enel X Juicebox
CVE-2023-29121 9.6 CRITICAL Exposed TCF agent service in Enel X Juicebox
CVE-2023-29125 9.0 CRITICAL Heap overflow in CM_main.exe binary in Enel X JuiceBox
CVE-2023-29117 8.8 HIGH Authentication Bypass in JuiceBox Web Manager interface
CVE-2023-29115 6.5 MEDIUM Denial of Service via Web Management interface in Enel X JuiceBox
CVE-2023-29114 5.7 MEDIUM Unauthorized System Log Disclosure in Enel X JuiceBox
CVE-2023-29116 4.3 MEDIUM PHP Information Disclosure in Enel X JuiceBox
CVE-2023-29126 4.2 MEDIUM Insecure loose comparison in Enel X JuiceBox

IV. Related Vulnerabilities

V. Comments for CVE-2023-29122

No comments yet


Leave a comment