Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2023-39171— SENEC Storage Box V1,V2 and V3 accidentially expose a management interface

Quick assessment

Affected
SENEC Storage Box V1
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

EnBw SENEC Legacy Storage Box是德国EnBw公司的一系列存储盒。 EnBw SENEC Legacy Storage Box V1、V2 和 V3 版本存在安全漏洞,该漏洞源于管理员凭据泄露,攻击者利用该漏洞可以访问管理 UI。

CVSS 7.2 · High EPSS 1.08% · P65
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2023-39171

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
SENEC Storage Box V1,V2 and V3 accidentially expose a management interface
Source: CVE Program / CVE List V5
Vulnerability Description
SENEC Storage Box V1,V2 and V3 accidentially expose a management UI accessible with publicly known admin credentials.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
将资源暴露给错误范围
Source: CVE Program / CVE List V5
Vulnerability Title
EnBw SENEC Legacy Storage Box 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
EnBw SENEC Legacy Storage Box是德国EnBw公司的一系列存储盒。 EnBw SENEC Legacy Storage Box V1、V2 和 V3 版本存在安全漏洞,该漏洞源于管理员凭据泄露,攻击者利用该漏洞可以访问管理 UI。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
SENEC Storage Box V1 before Nov. 2023 -
SENEC Storage Box V2 before Nov. 2023 -
SENEC Storage Box V3 before Nov. 2023 -

II. Public POCs for CVE-2023-39171

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2023-39171

请登录查看更多情报信息。

Mailing List Discussions for CVE-2023-39171 (1)

Same Patch Batch · SENEC · 2023-12-07 · 4 CVEs total

CVE-2023-39169 9.8 CRITICAL SENEC: Storage Box V1,V2 and V3 using default credentials
CVE-2023-39172 9.1 CRITICAL SENEC: Storage Box V1,V2 and V3 transmitting sensitive data unencrypted
CVE-2023-39167 7.5 HIGH SENEC: Storage Box V1,V2 and V3 affected by improper access control vulnerability

IV. Related Vulnerabilities