CVE-2024-10476

Quick assessment

Affected
Becton Dickinson & Co BD BACTEC™ Blood Culture System
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

BD BACTEC Blood Culture System等都是美国碧迪医疗(BD)公司的产品。BD BACTEC Blood Culture System是一个血液培养基系统。BD COR System是一个全自动和集成的高通量诊断系统。BD EpiCenter Microbiology Data Management System是一个微生物学数据管理系统。 BD多款产品存在安全漏洞,该漏洞源于使用了默认凭证,导致攻击者能够访问、修改或删除数据。以下产品受到影响:BD BACTEC Blood Cu

CVSS 8.0 · High EPSS 0.24% · P13

Possible ATT&CK Techniques 1 AI

T1078 · Valid Accounts
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-10476

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics Solution is only in scope of this vulnerability when installed on a NUC server. BD Synapsys™ Informatics Solution installed on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is not in scope.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
CWE-1392
Source: CVE Program / CVE List V5
Vulnerability Title
BD多款产品 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
BD BACTEC Blood Culture System等都是美国碧迪医疗(BD)公司的产品。BD BACTEC Blood Culture System是一个血液培养基系统。BD COR System是一个全自动和集成的高通量诊断系统。BD EpiCenter Microbiology Data Management System是一个微生物学数据管理系统。 BD多款产品存在安全漏洞,该漏洞源于使用了默认凭证,导致攻击者能够访问、修改或删除数据。以下产品受到影响:BD BACTEC Blood Cu
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

II. Public POCs for CVE-2024-10476

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-10476

请登录查看更多情报信息。

Vendor Advisories for CVE-2024-10476 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2024-10476

No comments yet


Leave a comment