Affected
Schneider Electric PowerLogic HDPM6000
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric PowerLogic HDPM6000是法国施耐德电气(Schneider Electric)公司的一个高密度计量系统。 Schneider Electric PowerLogic HDPM6000存在缓冲区错误漏洞,该漏洞源于包含一个内存缓冲区边界内操作限制不当漏洞,当攻击者向设备发送特定的 Modbus 写入数据包时,该漏洞可能允许未经授权的攻击者修改正常范围之外的配置值,这可能导致无效数据或 Web 界面功能丧失。

CVSS 6.5 · Medium EPSS 0.44% · P36

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-10498

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
内存缓冲区边界内操作的限制不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric PowerLogic HDPM6000 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric PowerLogic HDPM6000是法国施耐德电气(Schneider Electric)公司的一个高密度计量系统。 Schneider Electric PowerLogic HDPM6000存在缓冲区错误漏洞,该漏洞源于包含一个内存缓冲区边界内操作限制不当漏洞,当攻击者向设备发送特定的 Modbus 写入数据包时,该漏洞可能允许未经授权的攻击者修改正常范围之外的配置值,这可能导致无效数据或 Web 界面功能丧失。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric PowerLogic HDPM6000 Versions v0.62.7 and prior -

II. Public POCs for CVE-2024-10498

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-10498

请登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2025-01-17 · 8 CVEs total

CVE-2024-10497 8.8 HIGH Schneider Electric PowerLogic HDPM6000 安全漏洞
CVE-2024-12142 8.6 HIGH Schneider Electric Modicon M340 信息泄露漏洞
CVE-2024-12703 7.8 HIGH Schneider Electric RemoteConnect and SCADAPack 代码问题漏洞
CVE-2024-12476 7.8 HIGH Schneider Electric Web Designer 代码问题漏洞
CVE-2024-11425 7.5 HIGH Schneider Electric Modicon M580 安全漏洞
CVE-2024-12399 7.1 HIGH Schneider Electric Pro-face GP-Pro EX和Remote HMI 安全漏洞
CVE-2024-11139 Schneider Electric EcoStruxure Power Build Rapsody 缓冲区错误漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2024-10498

No comments yet


Leave a comment