Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2024-12399

Quick assessment

Affected
Schneider Electric Pro-face GP-Pro EX
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric Pro-face GP-Pro EX和Schneider Electric Pro-face Remote HMI都是法国施耐德电气(Schneider Electric)公司的产品。Schneider Electric Pro-face GP-Pro EX是一个人机界面操作管理系统。Schneider Electric Pro-face Remote HMI是一个用于 HMI 的远程监控软件。 Schneider Electric Pro-face GP-Pro E

CVSS 7.1 · High EPSS 0.17% · P6

Possible ATT&CK Techniques 1 AI

T1557 · Adversary-in-the-Middle
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-12399

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
通信信道中传输过程中消息完整性的不正确执行
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric Pro-face GP-Pro EX和Remote HMI 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Pro-face GP-Pro EX和Schneider Electric Pro-face Remote HMI都是法国施耐德电气(Schneider Electric)公司的产品。Schneider Electric Pro-face GP-Pro EX是一个人机界面操作管理系统。Schneider Electric Pro-face Remote HMI是一个用于 HMI 的远程监控软件。 Schneider Electric Pro-face GP-Pro E
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric Pro-face GP-Pro EX all version ~ v5.00.100 -
Schneider Electric Pro-face Remote HMI all versions ~ v1.70.000 -

II. Public POCs for CVE-2024-12399

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-12399

请登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2025-01-17 · 8 CVEs total

CVE-2024-10497 8.8 HIGH Schneider Electric PowerLogic HDPM6000 安全漏洞
CVE-2024-12142 8.6 HIGH Schneider Electric Modicon M340 信息泄露漏洞
CVE-2024-12703 7.8 HIGH Schneider Electric RemoteConnect and SCADAPack 代码问题漏洞
CVE-2024-12476 7.8 HIGH Schneider Electric Web Designer 代码问题漏洞
CVE-2024-11425 7.5 HIGH Schneider Electric Modicon M580 安全漏洞
CVE-2024-10498 6.5 MEDIUM Schneider Electric PowerLogic HDPM6000 缓冲区错误漏洞
CVE-2024-11139 Schneider Electric EcoStruxure Power Build Rapsody 缓冲区错误漏洞