Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2024-1683— DLL Injection in Tenable Identity Exposure Secure Relay

Quick assessment

Affected
Tenable Tenable Identity Exposure Secure Relay
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenable Identity Exposure Secure Relay是美国Tenable公司的一种使用传输层安全性 (TLS) 将 Active Directory 数据从网络传输到 Tenable Identity Exposure 的模式。 Tenable Identity Exposure Secure Relay 3.59.4之前版本存在安全漏洞,该漏洞源于存在DLL注入漏洞,攻击者可利用该漏洞通过修改TIE安全中继主机上的应用程序文件,从而覆盖配置和运行新的安全中继服务。

CVSS 7.3 · High EPSS 0.31% · P24
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-1683

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
DLL Injection in Tenable Identity Exposure Secure Relay
Source: CVE Program / CVE List V5
Vulnerability Description
A DLL injection vulnerability exists where an authenticated, low-privileged local attacker could modify application files on the TIE Secure Relay host, which could allow for overriding of the configuration and running of new Secure Relay services.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenable Identity Exposure Secure Relay 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenable Identity Exposure Secure Relay是美国Tenable公司的一种使用传输层安全性 (TLS) 将 Active Directory 数据从网络传输到 Tenable Identity Exposure 的模式。 Tenable Identity Exposure Secure Relay 3.59.4之前版本存在安全漏洞,该漏洞源于存在DLL注入漏洞,攻击者可利用该漏洞通过修改TIE安全中继主机上的应用程序文件,从而覆盖配置和运行新的安全中继服务。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenable Tenable Identity Exposure Secure Relay 3.42.17 ~ 3.59.4 -

II. Public POCs for CVE-2024-1683

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-1683

请登录查看更多情报信息。

Other References for CVE-2024-1683 (1)

IV. Related Vulnerabilities