Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2024-2547— Tenda AC18 R7WebsSecurityHandler stack-based overflow

Quick assessment

Affected
Tenda AC18
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC18是中国腾达(Tenda)公司的一款路由器。 Tenda AC18 V15.03.05.05 版本存在安全漏洞,该漏洞源于 R7WebsSecurityHandler 函数的 password 参数存在基于堆栈的缓冲区溢出。

CVSS 8.8 · High EPSS 1.19% · P65

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-2547

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC18 R7WebsSecurityHandler stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC18 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC18是中国腾达(Tenda)公司的一款路由器。 Tenda AC18 V15.03.05.05 版本存在安全漏洞,该漏洞源于 R7WebsSecurityHandler 函数的 password 参数存在基于堆栈的缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC18 15.03.05.05 -

II. Public POCs for CVE-2024-2547

# POC Description Source Link Shenlong Link
AI-Generated POC Verified env Premium
Qwen3.6-35B-A3B · 7827 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2024-2547

登录查看更多情报信息。

Vendor Advisories for CVE-2024-2547 (2)

Other References for CVE-2024-2547 (1)

Same Patch Batch · Tenda · 2024-03-17 · 5 CVEs total

CVE-2024-2558 8.8 HIGH Tenda AC18 execCommand formexeCommand stack-based overflow
CVE-2024-2546 8.8 HIGH Tenda AC18 fromSetWirelessRepeat stack-based overflow
CVE-2024-2560 4.3 MEDIUM Tenda AC18 SysToolRestoreSet fromSysToolRestoreSet cross-site request forgery
CVE-2024-2559 4.3 MEDIUM Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery

IV. Related Vulnerabilities

V. Comments for CVE-2024-2547

No comments yet


Leave a comment