Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2024-2764— Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

Quick assessment

Affected
Tenda AC10U
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC10是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC10U 15.03.06.48版本存在安全漏洞,该漏洞源于文件/goform/SetPptpServerCfg的函数formSetPPTPServer的参数endIP存在缓冲区溢出漏洞。

CVSS 8.8 · High EPSS 1.48% · P73
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-2764

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC10 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC10是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC10U 15.03.06.48版本存在安全漏洞,该漏洞源于文件/goform/SetPptpServerCfg的函数formSetPPTPServer的参数endIP存在缓冲区溢出漏洞。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC10U 15.03.06.48 -

II. Public POCs for CVE-2024-2764

# POC Description Source Link Shenlong Link
AI-Generated POC Verified env Premium
Qwen3.6-35B-A3B · 8302 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2024-2764

请登录查看更多情报信息。

Vendor Advisories for CVE-2024-2764 (2)

Other References for CVE-2024-2764 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2024-2764

No comments yet


Leave a comment