Vulnerability Title
Junos OS: SRX 5000 Series with SPC2: Processing of specific crafted packets when ALG is enabled causes a transit traffic Denial of Service
Source: NVD (National Vulnerability Database)
Vulnerability Description
An Incorrect Calculation of Buffer Size vulnerability in Juniper Networks Junos OS SRX 5000 Series devices using SPC2 line cards while ALGs are enabled allows an attacker sending specific crafted packets to cause a transit traffic Denial of Service (DoS). Continued receipt and processing of these specific packets will sustain the Denial of Service condition. This issue affects: Juniper Networks Junos OS SRX 5000 Series with SPC2 with ALGs enabled. * All versions earlier than 21.2R3-S7; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R2.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
缓冲区大小计算不正确
Source: NVD (National Vulnerability Database)
Vulnerability Title
Juniper Networks Junos OS SRX 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Juniper Networks Junos OS SRX是美国瞻博网络(Juniper Networks)公司的一套专用于该公司的硬件设备的网络操作系统。该操作系统提供了安全编程接口和Junos SDK。 Juniper Networks Junos OS SRX 5000 21.2R3-S7之前、21.4R3-S6之前、22.1R3-S5之前、22.2R3-S3之前、22.3R3-S2之前版本存在安全漏洞,该漏洞源于设备中使用 SPC2 线卡的缓冲区大小计算不正确,允许攻击者发送特定的精心设计的数据包
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
Juniper NetworksJunos OS 0 ~ 21.2R3-S7 -
II. Public POCs for CVE-2024-30405
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2024-30405
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2024-30405

No comments yet


Leave a comment