Vulnerability Information
Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.
Vulnerability Title
N/A
Vulnerability Description
A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes.
CVSS Information
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
Vulnerability Type
关键功能的认证机制缺失
Vulnerability Title
Siemens SINAMICS PERFECT HARMONY GH180 访问控制错误漏洞
Vulnerability Description
Siemens SINAMICS PERFECT HARMONY GH180是德国西门子(Siemens)公司的一款高压交流变频器。 Siemens SINAMICS PERFECT HARMONY GH180 V8.0至V8.3.3之前版本存在访问控制错误漏洞,该漏洞源于维护连接访问控制不当,可能导致任意配置更改。
CVSS Information
N/A
Vulnerability Type
N/A