Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2024-3879— Tenda W30E setcfm formSetCfm stack-based overflow

Quick assessment

Affected
Tenda W30E
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda W30E是中国腾达(Tenda)公司的一款路由器。 Tenda W30E 1.0.1.25(633)版本存在安全漏洞,该漏洞源于 /goform/setcfm 的formSetCfm函数存在安全问题,通过参数 funcpara1导致基于堆栈的缓冲区溢出。

CVSS 8.8 · High EPSS 1.45% · P71

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-3879

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda W30E setcfm formSetCfm stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda W30E 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda W30E是中国腾达(Tenda)公司的一款路由器。 Tenda W30E 1.0.1.25(633)版本存在安全漏洞,该漏洞源于 /goform/setcfm 的formSetCfm函数存在安全问题,通过参数 funcpara1导致基于堆栈的缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda W30E 1.0.1.25(633) -

II. Public POCs for CVE-2024-3879

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 6712 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2024-3879

登录查看更多情报信息。

Vendor Advisories for CVE-2024-3879 (2)

Other References for CVE-2024-3879 (1)

Same Patch Batch · Tenda · 2024-04-16 · 9 CVEs total

CVE-2024-3874 8.8 HIGH Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow
CVE-2024-3875 8.8 HIGH Tenda F1202 Natlimit fromNatlimit stack-based overflow
CVE-2024-3876 8.8 HIGH Tenda F1202 VirtualSer fromVirtualSer stack-based overflow
CVE-2024-3877 8.8 HIGH Tenda F1202 fromqossetting stack-based overflow
CVE-2024-3878 8.8 HIGH Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
CVE-2024-3881 8.8 HIGH Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow
CVE-2024-3882 8.8 HIGH Tenda W30E fromRouteStatic stack-based overflow
CVE-2024-3880 6.3 MEDIUM Tenda W30E WriteFacMac formWriteFacMac os command injection

IV. Related Vulnerabilities

V. Comments for CVE-2024-3879

No comments yet


Leave a comment