Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2024-42967

Quick assessment

Affected
n/a n/a
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

TOTOLINK LR350是中国吉翁电子(TOTOLINK)公司的一款无线路由器。 TOTOLINK LR350 V9.3.5u.6369_B20220309 版本存在安全漏洞,该漏洞源于 /cgi-bin/ExportSettings.sh 文件中包含一个访问控制错误漏洞。

AI Predicted 9.1 Difficulty: Easy EPSS 0.60% · P46
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-42967

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Incorrect access control in TOTOLINK LR350 V9.3.5u.6369_B20220309 allows attackers to obtain the apmib configuration file, which contains the username and the password, via a crafted request to /cgi-bin/ExportSettings.sh.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
N/A
Source: CVE Program / CVE List V5
Vulnerability Title
TOTOLINK LR350 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
TOTOLINK LR350是中国吉翁电子(TOTOLINK)公司的一款无线路由器。 TOTOLINK LR350 V9.3.5u.6369_B20220309 版本存在安全漏洞,该漏洞源于 /cgi-bin/ExportSettings.sh 文件中包含一个访问控制错误漏洞。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
- n/a n/a -

II. Public POCs for CVE-2024-42967

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-42967

登录查看更多情报信息。

Same Patch Batch · n/a · 2024-08-15 · 54 CVEs total

CVE-2024-42968 Tenda FH1206 安全漏洞
CVE-2024-42986 Tenda FH1206 安全漏洞
CVE-2024-42969 Tenda FH1206 安全漏洞
CVE-2024-42985 Tenda FH1206 安全漏洞
CVE-2024-42980 Tenda FH1206 安全漏洞
CVE-2024-42974 Tenda FH1206 安全漏洞
CVE-2024-42947 Tenda FH1201 安全漏洞
CVE-2024-42984 Tenda FH1206 安全漏洞
CVE-2024-42945 Tenda FH1201 安全漏洞
CVE-2024-42949 Tenda FH1201 安全漏洞
CVE-2024-42676 Huizhi enterprise resource management system 安全漏洞
CVE-2024-42943 Tenda FH1201 缓冲区错误漏洞
CVE-2024-42941 Tenda FH1201 缓冲区错误漏洞
CVE-2024-42677 Huizhi enterprise resource management system 安全漏洞
CVE-2024-42979 Tenda FH1206 安全漏洞
CVE-2024-42952 Tenda FH1201 缓冲区错误漏洞
CVE-2024-42680 Super easy enterprise management system 安全漏洞
CVE-2024-42966 TOTOLINK N350RT 安全漏洞
CVE-2024-42951 Tenda FH1201 缓冲区错误漏洞
CVE-2024-42983 Tenda FH1206 安全漏洞

Showing top 20 of 54 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2024-42967

No comments yet


Leave a comment