CVE-2024-4465— Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0

Quick assessment

Affected
Nozomi Networks Guardian
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Nozomi Networks Guardian/CMC是美国Nozomi Networks公司的一个中央管理控制台。 Nozomi Networks Guardian/CMC存在安全漏洞,该漏洞源于报告部分的访问控制未对有限权限用户正确实施,可能导致数据完整性部分丢失、有限的拒绝服务(DoS)影响以及信息泄露。

CVSS 6.0 · Medium EPSS 0.22% · P12
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-4465

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0
Source: CVE Program / CVE List V5
Vulnerability Description
An access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges. If a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
授权机制不正确
Source: CVE Program / CVE List V5
Vulnerability Title
Nozomi Networks Guardian/CMC 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Nozomi Networks Guardian/CMC是美国Nozomi Networks公司的一个中央管理控制台。 Nozomi Networks Guardian/CMC存在安全漏洞,该漏洞源于报告部分的访问控制未对有限权限用户正确实施,可能导致数据完整性部分丢失、有限的拒绝服务(DoS)影响以及信息泄露。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Nozomi Networks Guardian 0 ~ 24.2.0 -
Nozomi Networks CMC 0 ~ 24.2.0 -

II. Public POCs for CVE-2024-4465

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-4465

请登录查看更多情报信息。

IV. Related Vulnerabilities

V. Comments for CVE-2024-4465

No comments yet