Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2024-45471

Quick assessment

Affected
Siemens Teamcenter Visualization V14.2
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens Tecnomatix Plant Simulation是德国西门子(Siemens)公司的一个工控设备。利用离散事件仿真的强大功能进行生产量分析和优化,进而改善制造系统性能。 Siemens Tecnomatix Plant Simulation V2302版本至V2302.0016之前版本和V2404版本至V2404.0005之前版本存在缓冲区错误漏洞,该漏洞源于在解析特制的 WRL 文件时包含越界写入漏洞。攻击者利用该漏洞可以在当前进程中执行任意代码。

CVSS 7.8 · High EPSS 0.25% · P17
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-45471

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
跨界内存写
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Tecnomatix Plant Simulation是德国西门子(Siemens)公司的一个工控设备。利用离散事件仿真的强大功能进行生产量分析和优化,进而改善制造系统性能。 Siemens Tecnomatix Plant Simulation V2302版本至V2302.0016之前版本和V2404版本至V2404.0005之前版本存在缓冲区错误漏洞,该漏洞源于在解析特制的 WRL 文件时包含越界写入漏洞。攻击者利用该漏洞可以在当前进程中执行任意代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens Teamcenter Visualization V14.2 0 ~ V14.2.0.14 -
Siemens Teamcenter Visualization V14.3 0 ~ V14.3.0.12 -
Siemens Teamcenter Visualization V2312 0 ~ V2312.0008 -
Siemens Tecnomatix Plant Simulation V2302 0 ~ V2302.0016 -
Siemens Tecnomatix Plant Simulation V2404 0 ~ V2404.0005 -

II. Public POCs for CVE-2024-45471

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-45471

登录查看更多情报信息。

Vendor Advisories for CVE-2024-45471 (1)

Same Patch Batch · Siemens · 2024-10-08 · 28 CVEs total

CVE-2024-47553 9.9 CRITICAL Siemens SINEC Security Monitor 参数注入漏洞
CVE-2024-41798 9.8 CRITICAL Siemens SENTRON 7KM PAC3200 授权问题漏洞
CVE-2024-47562 8.8 HIGH Siemens SINEC Security Monitor 安全漏洞
CVE-2023-52952 8.5 HIGH Siemens HiMed Cockpit 安全漏洞
CVE-2024-45473 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-41902 7.8 HIGH Siemens JT2GO 安全漏洞
CVE-2024-41981 7.8 HIGH Siemens Simcenter Nastran 2306、Simcenter Nastran 2312和Simcenter Nastran 2406 安全漏洞
CVE-2024-45463 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45464 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45465 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45466 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45467 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45468 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45469 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45470 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45472 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45474 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-45475 7.8 HIGH Siemens Tecnomatix Plant Simulation 缓冲区错误漏洞
CVE-2024-47046 7.8 HIGH Siemens Simcenter Nastran 缓冲区错误漏洞
CVE-2024-47194 6.7 MEDIUM Siemens ModelSim 代码问题漏洞

Showing top 20 of 28 CVEs. View all on vendor page &rarr; →