Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2024-5681

Quick assessment

Affected
Schneider Electric EcoStruxure Foxboro DCS Core Control Services
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric EcoStruxure Foxboro DCS是法国施耐德电气(Schneider Electric)公司的一个创新的容错、高度可用的控制组件。 Schneider Electric EcoStruxure Foxboro DCS Core Control Services 9.8及之前版本存在输入验证错误漏洞,该漏洞源于当使用Foxboro.sys驱动程序中的IOCTL调用编写脚本/程序时,会导致本地拒绝服务、权限提升和潜在的内核执行。

CVSS 7.8 · High EPSS 0.24% · P14
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-5681

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
输入验证不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric EcoStruxure Foxboro DCS 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric EcoStruxure Foxboro DCS是法国施耐德电气(Schneider Electric)公司的一个创新的容错、高度可用的控制组件。 Schneider Electric EcoStruxure Foxboro DCS Core Control Services 9.8及之前版本存在输入验证错误漏洞,该漏洞源于当使用Foxboro.sys驱动程序中的IOCTL调用编写脚本/程序时,会导致本地拒绝服务、权限提升和潜在的内核执行。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric EcoStruxure Foxboro DCS Core Control Services Versions 9.8 and prior -

II. Public POCs for CVE-2024-5681

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-5681

请登录查看更多情报信息。

Other References for CVE-2024-5681 (1)

Same Patch Batch · Schneider Electric · 2024-07-11 · 6 CVEs total

CVE-2024-6407 9.8 CRITICAL Schneider Electric Wiser Home Controller WHC-5918A 信息泄露漏洞
CVE-2024-2602 7.3 HIGH Schneider Electric FoxRTU Station 路径遍历漏洞
CVE-2024-5679 7.1 HIGH EcoStruxure Foxboro DCS Core Control Services 缓冲区错误漏洞
CVE-2024-5680 7.1 HIGH Schneider Electric EcoStruxure Foxboro DCS 输入验证错误漏洞
CVE-2024-6528 5.4 MEDIUM Schneider Electric Modicon Controllers 跨站脚本漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2024-5681

No comments yet


Leave a comment