Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2024-8935

Quick assessment

Affected
Schneider Electric Modicon M340 CPU (part numbers BMXP34*)
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric Modicon M340是法国施耐德电气(Schneider Electric)公司的一款用于工业过程和基础设施的中程PLC(可编程逻辑控制器)。 Schneider Electric Modicon M340存在安全漏洞,该漏洞源于存在通过欺骗绕过身份验证漏洞,当有效用户建立通信会话时,在控制器和工程工作站之间进行中间人攻击,可能导致拒绝服务以及控制器机密性和完整性的丧失。

CVSS 7.5 · High EPSS 0.50% · P41
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-8935

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
使用欺骗进行的认证绕过
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric Modicon M340 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Modicon M340是法国施耐德电气(Schneider Electric)公司的一款用于工业过程和基础设施的中程PLC(可编程逻辑控制器)。 Schneider Electric Modicon M340存在安全漏洞,该漏洞源于存在通过欺骗绕过身份验证漏洞,当有效用户建立通信会话时,在控制器和工程工作站之间进行中间人攻击,可能导致拒绝服务以及控制器机密性和完整性的丧失。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric Modicon M340 CPU (part numbers BMXP34*) All versions since SV3.60 -
Schneider Electric Modicon MC80 (part numbers BMKC80) All versions -
Schneider Electric Modicon Momentum Unity M1E Processor (171CBU*) All Versions -

II. Public POCs for CVE-2024-8935

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-8935

请登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2024-11-13 · 7 CVEs total

CVE-2024-10575 9.8 CRITICAL Schneider Electric EcoStruxure IT Gateway 安全漏洞
CVE-2024-8938 8.1 HIGH Schneider Electric Modicon M340 缓冲区错误漏洞
CVE-2024-8933 7.5 HIGH Schneider Electric Modicon M340 安全漏洞
CVE-2024-9409 7.5 HIGH Schneider Electric多款产品 资源管理错误漏洞
CVE-2024-8937 6.5 MEDIUM Schneider Electric Modicon M340 缓冲区错误漏洞
CVE-2024-8936 6.5 MEDIUM Schneider Electric 输入验证错误漏洞

IV. Related Vulnerabilities