CVE-2025-11121— Tenda AC18 AdvSetLanip command injection

Quick assessment

Affected
Tenda AC18
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC18是中国腾达(Tenda)公司的一款路由器。 Tenda AC18 15.03.05.19版本存在命令注入漏洞,该漏洞源于对文件/goform/AdvSetLanip中参数lanIp的错误操作,可能导致远程命令注入攻击。

CVSS 6.3 · Medium EPSS 3.74% · P89
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-11121

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC18 AdvSetLanip command injection
Source: CVE Program / CVE List V5
Vulnerability Description
A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
在命令中使用的特殊元素转义处理不恰当(命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC18 命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC18是中国腾达(Tenda)公司的一款路由器。 Tenda AC18 15.03.05.19版本存在命令注入漏洞,该漏洞源于对文件/goform/AdvSetLanip中参数lanIp的错误操作,可能导致远程命令注入攻击。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC18 15.03.05.19 -

II. Public POCs for CVE-2025-11121

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-11121

登录查看更多情报信息。

Proof of Concept for CVE-2025-11121 (1)

Same Patch Batch · Tenda · 2025-09-28 · 6 CVEs total

CVE-2025-11123 8.8 HIGH Tenda AC18 saveAutoQos stack-based overflow
CVE-2025-11122 8.8 HIGH Tenda AC18 WizardHandle stack-based overflow
CVE-2025-11120 8.8 HIGH Tenda AC8 SetServerConfig formSetServerConfig buffer overflow
CVE-2025-11117 8.8 HIGH Tenda CH22 GstDhcpSetSer formWrlExtraGet buffer overflow
CVE-2025-11091 8.8 HIGH Tenda AC21 SetStaticRouteCfg sscanf buffer overflow

IV. Related Vulnerabilities

V. Comments for CVE-2025-11121

No comments yet


Leave a comment