Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-11523— Tenda AC7 AdvSetLanip command injection

Quick assessment

Affected
Tenda AC7
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC7是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC7 15.03.06.44版本存在命令注入漏洞,该漏洞源于对文件/goform/AdvSetLanip中参数lanIp的错误操作,可能导致远程命令注入攻击。

CVSS 6.3 · Medium EPSS 3.74% · P90

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-11523

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC7 AdvSetLanip command injection
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
在命令中使用的特殊元素转义处理不恰当(命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC7 命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC7是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC7 15.03.06.44版本存在命令注入漏洞,该漏洞源于对文件/goform/AdvSetLanip中参数lanIp的错误操作,可能导致远程命令注入攻击。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC7 15.03.06.44 cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2025-11523

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-11523

请登录查看更多情报信息。

Other References for CVE-2025-11523 (1)

Same Patch Batch · Tenda · 2025-10-09 · 8 CVEs total

CVE-2025-11549 8.8 HIGH Tenda W12 HTTP Request modules wifiMacFilterSet stack-based overflow
CVE-2025-11528 8.8 HIGH Tenda AC7 saveAutoQos stack-based overflow
CVE-2025-11527 8.8 HIGH Tenda AC7 fast_setting_pppoe_set stack-based overflow
CVE-2025-11526 8.8 HIGH Tenda AC7 WifiMacFilterSet stack-based overflow
CVE-2025-11525 8.8 HIGH Tenda AC7 SetUpnpCfg stack-based overflow
CVE-2025-11524 8.8 HIGH Tenda AC7 SetDDNSCfg stack-based overflow
CVE-2025-11550 6.5 MEDIUM Tenda W12 HTTP Request modules wifiScheduledSet null pointer dereference