CVE-2025-1316— Edimax IC-7100 IP Camera OS Command Injection

Quick assessment

Affected
Edimax IC-7100 IP Camera
Exploitation
Confirmed exploitation in the wild; remediate immediately
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Edimax IC-7100是中国讯舟(Edimax)公司的一款安全摄像头。 Edimax IC-7100 IP Camera存在操作系统命令注入漏洞,该漏洞源于未正确中和请求,可能导致远程代码执行。

CVSS 9.8 · Critical KEV EPSS 73.24% · P99

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-1316

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Edimax IC-7100 IP Camera OS Command Injection
Source: CVE Program / CVE List V5
Vulnerability Description
Edimax IC-7100 does not properly neutralize requests. An attacker can create specially crafted requests to achieve remote code execution on the device
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Edimax IC-7100 操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Edimax IC-7100是中国讯舟(Edimax)公司的一款安全摄像头。 Edimax IC-7100 IP Camera存在操作系统命令注入漏洞,该漏洞源于未正确中和请求,可能导致远程代码执行。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
Edimax IC-7100 IP Camera All -

II. Public POCs for CVE-2025-1316

# POC Description Source Link Shenlong Link
1 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') (CWE-78) https://github.com/Rimasue/CVE-2025-1316 POC Details
2 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') (CWE-78) https://github.com/slockit/CVE-2025-1316 POC Details
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-1316

登录查看更多情报信息。

Vendor Advisories for CVE-2025-1316 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2025-1316

No comments yet


Leave a comment