Quick assessment

Affected
Schneider Electric EcoStruxure™ Process Expert
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric EcoStruxure Process Expert是法国施耐德电气(Schneider Electric)公司的一个用于设计、操作和维护整个工厂的下一代过程自动化系统。 Schneider Electric EcoStruxure Process Expert存在安全漏洞,该漏洞源于默认权限不正确,可能导致本地用户在服务重启时修改安装文件夹中的可执行服务二进制文件,从而通过反向shell进行权限提升。

AI Predicted 7.8 Difficulty: Moderate EPSS 0.11% · P1

Possible ATT&CK Techniques 1 AI

T1055 · Process Injection
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-13905

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Source: CVE Program / CVE List V5
Vulnerability Type
缺省权限不正确
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric EcoStruxure Process Expert 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric EcoStruxure Process Expert是法国施耐德电气(Schneider Electric)公司的一个用于设计、操作和维护整个工厂的下一代过程自动化系统。 Schneider Electric EcoStruxure Process Expert存在安全漏洞,该漏洞源于默认权限不正确,可能导致本地用户在服务重启时修改安装文件夹中的可执行服务二进制文件,从而通过反向shell进行权限提升。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric EcoStruxure™ Process Expert Versions prior to 2025 -
Schneider Electric EcoStruxure™ Process Expert for AVEVA System Platform All versions -