Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-20014— mySCADA myPRO Manager OS Command Injection

Quick assessment

Affected
mySCADA myPRO Manager
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

mySCADA myPRO是mySCADA公司的一个专业的 HMI/SCADA 系统,主要设计用于工业过程的可视化和控制。 mySCADA myPRO存在操作系统命令注入漏洞,该漏洞源于无法正确处理发送到特定端口的带有版本信息的 POST 请求。攻击者利用该漏洞可以在受影响的系统上执行任意命令。

CVSS 9.8 · Critical EPSS 1.28% · P69

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-20014

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
mySCADA myPRO Manager OS Command Injection
Source: CVE Program / CVE List V5
Vulnerability Description
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
mySCADA myPRO 操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
mySCADA myPRO是mySCADA公司的一个专业的 HMI/SCADA 系统,主要设计用于工业过程的可视化和控制。 mySCADA myPRO存在操作系统命令注入漏洞,该漏洞源于无法正确处理发送到特定端口的带有版本信息的 POST 请求。攻击者利用该漏洞可以在受影响的系统上执行任意命令。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
mySCADA myPRO Manager 0 ~ 1.3 -
mySCADA myPRO Runtime 0 ~ 9.2.1 -

II. Public POCs for CVE-2025-20014

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-20014

请登录查看更多情报信息。

IV. Related Vulnerabilities

V. Comments for CVE-2025-20014

No comments yet


Leave a comment