Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2025-2370— TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow

Quick assessment

Affected
TOTOLINK EX1800T
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

TOTOLINK EX1800T是中国吉翁电子(TOTOLINK)公司的一款 Wi-Fi 范围扩展器。 TOTOLINK EX1800T 9.1.0cu.2112_B20220316及之前版本存在安全漏洞,该漏洞源于栈缓冲区溢出,可能导致远程攻击者执行任意代码。

CVSS 8.8 · High EPSS 1.12% · P63

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-2370

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was found in TOTOLINK EX1800T up to 9.1.0cu.2112_B20220316. It has been declared as critical. Affected by this vulnerability is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliSsid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
TOTOLINK EX1800T 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
TOTOLINK EX1800T是中国吉翁电子(TOTOLINK)公司的一款 Wi-Fi 范围扩展器。 TOTOLINK EX1800T 9.1.0cu.2112_B20220316及之前版本存在安全漏洞,该漏洞源于栈缓冲区溢出,可能导致远程攻击者执行任意代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
TOTOLINK EX1800T 9.1.0cu.2112_B20220316 -

II. Public POCs for CVE-2025-2370

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-2370

登录查看更多情报信息。

Vendor Advisories for CVE-2025-2370 (3)

News Coverage for CVE-2025-2370 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2025-2370

No comments yet


Leave a comment