Affected
Siemens OZW672
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens OZW672是德国西门子(Siemens)公司的一款楼宇控制器。 Siemens OZW672 V8.0之前版本存在操作系统命令注入漏洞,该漏洞源于exportDiagramPage端点输入参数清理不足,可能导致执行任意代码。

CVSS 10.0 · Critical EPSS 0.98% · P61
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-26389

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens OZW672 操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens OZW672是德国西门子(Siemens)公司的一款楼宇控制器。 Siemens OZW672 V8.0之前版本存在操作系统命令注入漏洞,该漏洞源于exportDiagramPage端点输入参数清理不足,可能导致执行任意代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens OZW672 0 ~ V8.0 -
Siemens OZW772 0 ~ V8.0 -

II. Public POCs for CVE-2025-26389

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-26389

请登录查看更多情报信息。

Vendor Advisories for CVE-2025-26389 (1)

Same Patch Batch · Siemens · 2025-05-13 · 36 CVEs total

CVE-2025-32469 9.9 CRITICAL siemens多款产品 安全漏洞
CVE-2025-33024 9.9 CRITICAL Siemens多款产品 安全漏洞
CVE-2025-33025 9.9 CRITICAL Siemens多款产品 安全漏洞
CVE-2025-26390 9.8 CRITICAL Siemens OZW672和Siemens OZW772 SQL注入漏洞
CVE-2025-31930 8.8 HIGH Siemens VersiCharge AC Series 安全漏洞
CVE-2025-40566 8.8 HIGH Siemens SIMATIC PCS neo 代码问题漏洞
CVE-2025-40582 7.8 HIGH Siemens SCALANCE LPE9403 操作系统命令注入漏洞
CVE-2025-32454 7.8 HIGH Siemens Teamcenter Visualization 缓冲区错误漏洞
CVE-2025-40574 7.8 HIGH Siemens SCALANCE LPE9403 安全漏洞
CVE-2025-30176 7.5 HIGH Siemens多款产品 缓冲区错误漏洞
CVE-2024-23815 7.5 HIGH Siemens Desigo CC 访问控制错误漏洞
CVE-2025-24007 7.5 HIGH Siemens SIRIUS 3RK3 Modular Safety System和Siemens SIRIUS Safety Relays 3SK2 加密问题漏洞
CVE-2025-30174 7.5 HIGH Siemens多款产品 缓冲区错误漏洞
CVE-2025-30175 7.5 HIGH Siemens多款产品 缓冲区错误漏洞
CVE-2025-40581 7.1 HIGH Siemens SCALANCE LPE9403 安全漏洞
CVE-2025-40579 6.7 MEDIUM Siemens SCALANCE LPE9403 安全漏洞
CVE-2025-40580 6.7 MEDIUM Siemens SCALANCE LPE9403 安全漏洞
CVE-2025-40556 6.5 MEDIUM Siemens BACnet ATEC 输入验证错误漏洞
CVE-2024-51444 6.5 MEDIUM Siemens Polarion SQL注入漏洞
CVE-2024-51445 6.5 MEDIUM Siemens Polarion 代码问题漏洞

Showing top 20 of 36 CVEs. View all on vendor page &rarr; →